Armature The moving magnetic member of an electromagnetic relay structure
  .
Capacitance The maximum allowable capacitive coupling between two specified test points
  .
Coil Voltage (maximum) The maximum coil voltage which can be applied to the coil over the temperature range, without damaging the coil.
  .
Contact (Form C) Break before Make, or Transfer
  .
Contact Bounce Intermittent and undesired opening of closed contacts or closing of open contacts, of a relay.
  .
Contact Bounce Time For a contact which is closing (opening) its circuit, the time internal between the instant when the contact circuit first closes (opens) and the instant when the circuit is finally closed (opened).
  .
Carry Current The amount of current which can safely flow through closed contacts, when the contacts are opened and closed with no load applied.
  .
Cycle One opening and one closure of a contact set
  .
DPDT Double Pole Double Throw relay
  .
Drop-out Value A monostable relay drops out when it changes from an energized to an unenergized condition.
  .
Isolation The value of insulation resistance, dielectric strength and capacitance measured between the input and outputs. The leakage of an RF signal between mutually isolated points.
  .
Low level Load Load level which will have minimal effect on contact life and performance.
  .
Nominai Coil Voltage The coil voltage at which the relay is intended to operate.
  .
Operate Time The interval of time between the application of the operate value and the first closing (or opening) of the contact circuit.
  .
Pick-up (Pull-in) Value As the current or voltage on an unoperated relay is increased, the minimum value at which all contacts will change state.
  .
Release Time The interval of time between the application of the release value and the first opening (or closing) of the contact circuit.
  .
SPDT Single Pole Double Throw relay.
  .
Crosstalk The electrical coupling between a closed contact circuit and other open or closed contacts on the same relay or switch, expressed in decibel down from the signal level.
  .
Contact Stabilisation time The interval of time, following operate or release time, to reach and maintain the static contact resistance value of the relay. It is the sum of the contact bounce time and the time for dynamic contact resistance to stabilise to the static contact resistance
  .
VSWR Voltage Standing Wave Radio. A measurement of the reflected RF signal.
 